- 3100 Lincoln St E, Canton, OH 44707
-
Monday 7:00 am – 4:00 pm Tuesday 7:00 am – 4:00 pm Wednesday Closed Thursday 7:00 am – 4:00 pm Friday 7:00 am – 4:00 pm Saturday Closed Sunday Closed
- Equipment: VNG/Landa Stationary Pressure Washer
- Symptom: Runs for 10 minutes then shuts down. The equipment hadn't been serviced in quite some time. Secondary Symptom: After the equipment was running properly, it was identified that the supply plumbing to the pressure washer and the pressure lines out to the Wash Bay had internal corrosion.
-
Solution:
Replace the Overload Relay, the Contactor and the Unloader.
Secondary Solution: Remove galvanized pipe and install stainless steel pipe throughout system.